1 Service
1.1 Language
English, Deutsch, Français, Svenska, Spanish
1.2 Time & Date
Select the date or time line with (+) or (-)
1.3 System
Choose between 5 systems, System 1 is default
1.3.1 System 1
Basic system, with 1 tank, 1 pump, 1 collector array and 2 or 3 sensors
1.3.2 System 2
System with 2 tanks, 1 pump, 1 valve, 1 collector array and 3 sensors
1.3.3 System 3
System with 2 tanks, 2 pumps, 1 collector array and 3 sensors
1.3.4 System 4
System with 1 tank, 1 pump, 1 valve, 2 collector arrays with 2 different cardinal directions (East / West) and 3
sensors
1.3.5 System 5
System with 1 tank, 2 pumps, 2 collector arrays with 2 different cardinal directions (East / West) and 3 sensors
1.4 Extra function
Choose between 3 extra functions
1.4.1 Thermostat
Use to connect an auxiliary or back-up heat source to your system
1.4.2 Cooling
Use to cool down the primary solar tank during times of high solar irradiation
1.4.3 Diffcontrol
Use to transfer heated water from one storage tank to another (System 1 only)
1.5 External Sensor
Use for collectors that require the sensor to be mounted on the piping external to the collector manifold
1.6 Protection function
Will automatically activate, when the collector temperature reaches the Maxtemp
1.6.1 MaxTemp
Adjustable from 230°F to 302°F with factory default set at 248°F
1.6.2 Cooling
Activates the solar pump (P1 or P2), if the temperature on the collector arrays (T1 or T4) exceeds the collector
Maxtemp
1.6.3 Overheat protection
Will stop all collector circulation, when the collector temperature registers more than 50°F above the collector
Maxtemp
1.6.4 Freeze Protection
Will keep the solar panel temperature above the Freeze Protection Temperature setting level by activating the
solar pump
1.7 Flow meter
If no flow meter is installed, you must manually enter the max (100%) pump flow in gallons/minute
1.8 Reset to Factory default settings
Reset all settings to their factory default
1.9 Reset operation time
Reset the all of the operation hours to zero
1.10 Time graph temperatures
Adjusts the graphical scale for the Temp vs. Time graphs
1.11 Time graph operation
Adjusts the graphical scale for the Operation h menu vs. time graphs
1.12 Calibration of sensors
Calibrate all the temperature sensors connected to your system
1.13 US Version
Allows selection of the units of measurement that will be displayed
1.14 Pump P1
Choose the type of the pump speed control used on the output P1 (Type: No SC, PhAC SC or PWM SC)
1.15 Pump P2
Choose the type of the pump speed control used on the output P2 (Type: No SC, PhAC SC or PWM SC)
1.16 GDS1
Select inputs for analog GRUNDFOS sensors (Type: NC not connected, VFS Flow sensor or VPS pressure
sensor)
1.17 GDS2
Select inputs for analog GRUNDFOS sensors (Type: NC not connected, VFS Flow sensor or VPS pressure
sensor)
1.18 Priority tank
Designate one of the system tanks as priority (tank1 or tank2) Will only display if configuring a system with
two tanks
2 Setting
2.1 Maxtemp tank1
Maximum desired water temperature in tank1
2.2 dTMax tank1
Difference (ΔT) between collector temperature (T1) and tank1 temperature (T2) - will engage pump1
2.3 dTMin tank1
Difference (ΔT) between collector temperature (T1) and Tank1 temperature (T2) - will disengage pump1
2.4 Maxtemp tank2
Maximum desired water temperature in tank2
2.5 dTMax tank2
Difference (ΔT) between collector temperature (T1) and tank2 temperature (T4) - will engage pump1 with system2
or pump2 with system3
2.6 dTMin tank2
Difference (ΔT) between collector temperature (T1) and tank2 temperature (T4) - will disengage pump1 with
system2 or pump2 with system3
2.7 Mintemp Prio tank
Minimum temperature setting for the priority tank of systems with two tanks
2.8 Min rev pump
Minimum speed of pumps set to Phase SC (PhAC SC)
2.9 Boost time (Booster pump)
Select the running time of P2 (Booster Pump)
2.10 Mintemp Collector
Select the minimum collector temperature required for system start-up
Apricus Solar Collector Installation & Operation Manual - USA
Copyright © 2011 – Apricus Inc Doc: A7-05.4.12-PB Page 50 of 129